Comparison
Astha Jacking Method Is More Excellent Than Traditional Method for Field Erected Tanks
Comparison between the traditional method and the jacking method
Large vertical storage tanks generally refer to storage tanks whose diameter is more than 5 meters, especially those whose maximum diameter can be up to 40m-50m and whose maximum height can be up to more than 10 meters. For the fabrication and installation of this kind of large storage tank, as it is unachievable to transport an assembled tank, field erection is the most common method. There are several erection methods for field-erected tanks, such as the traditional method, jacking method, and integral lifting after the site prefabrication.
The traditional method is erecting on a ground base of a storage tank, after one section is assembled, the scaffold tower will be added a layer as the tank increases, because of the high operation, and this method is more dangerous.


The jacking method is erecting the tank starting from the roof of a tank on the ground, after one section is installed, the tank will be lifted to the next height by cranes and then installed in the next section.
This assembly method has the advantages of convenient erection, fast progress, production safety, etc.; therefore, it has been widely used all over the world.